Multi-sensor temperature measurement: 8-channel, 24-bit inputs supporting thermocouples, RTDs, thermistors, semiconductor sensors and voltage, with built-in cold-junction compensation (CJC) and open-thermocouple detection (OTD).
MCC USB-TEMP and USB-TC Series Temperature DAQ Modules
MCC USB-TEMP and USB-TC are 8-channel, 24-bit USB temperature DAQ modules at 2 Hz/channel, supporting thermocouples, RTDs, thermistors, semiconductor sensors and voltage, with cold-junction compensation and 8 digital I/O lines.
What this solution covers
Digital I/O and counter: 8 TTL-compatible digital I/O lines; AI models add one 32-bit event counter (up to 1 MHz); USB-powered with no external supply required.
Models and software: USB-TC/USB-TEMP offer all-temperature channels, while USB-TC-AI/USB-TEMP-AI add 4 voltage inputs; supplied with DAQami, TracerDAQ Pro and DASYLab, supporting Windows/Linux/Android.
Technical details & configuration
Source: MCC (Measurement Computing), now part of Digilent. Specifications have been checked against the source description and official MCC/Digilent documentation. Confirm exact models and availability with the Digilent official site.
| Item | Published information | Source |
|---|---|---|
| Analog inputs | 8 differential analog inputs | [1] |
| Resolution | 24-bit | [1] |
| Sample rate | Up to 2 Hz/channel (16 S/s total) | [1] |
| Measurement types | Thermocouple, RTD, thermistor, semiconductor sensor, voltage | [1] |
| USB-TC | 8 thermocouple inputs (types J/K/R/S/T/N/E/B) | [1] |
| USB-TEMP | 8 temperature inputs (thermocouple/RTD/thermistor/semiconductor) | [1] |
| USB-TC-AI | 4 thermocouple + 4 voltage inputs (±10 V, etc.) | [1] |
| USB-TEMP-AI | 4 temperature + 4 voltage inputs (±1.25 to ±10 V) | [1] |
Provide sensor type (thermocouple type/RTD/thermistor/semiconductor/voltage), channel count and whether voltage inputs are needed (AI models), sample rate and accuracy requirements, digital I/O and counter needs, whether DAQami/DASYLab/TracerDAQ Pro software is required, and operating system (Windows/Linux/Android) needs.
Questions before you start
Do the listed values apply to every configuration?
Source: MCC (Measurement Computing), now part of Digilent. Specifications have been checked against the source description and official MCC/Digilent documentation. Confirm exact models and availability with the Digilent official site.
What should I prepare for a technical discussion?
Provide sensor type (thermocouple type/RTD/thermistor/semiconductor/voltage), channel count and whether voltage inputs are needed (AI models), sample rate and accuracy requirements, digital I/O and counter needs, whether DAQami/DASYLab/TracerDAQ Pro software is required, and operating system (Windows/Linux/Android) needs.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.