High-precision simultaneous sampling: 8 18-bit analog inputs (software-selectable differential or single-ended per channel) sampled simultaneously, up to 200 kS/s/ch for USB-1808X and 50 kS/s/ch for USB-1808; ranges of ±10 V, ±5 V, 0–10 V and 0–5 V.
MCC USB-1808 Series Simultaneous-Sampling USB DAQ Devices
MCC USB-1808 is an 18-bit simultaneous-sampling DAQ device with 8 SE/DIFF inputs up to 200 kHz/channel (X models), 2 16-bit analog outputs, 4 digital I/O, 2 counters and 2 quadrature encoders, supporting synchronous I/O, with OEM board-only versions.
What this solution covers
Synchronous I/O and counting: 2 16-bit ±10 V analog outputs, 4 digital I/O, two 32-bit general-purpose counters (up to 50 MHz), two quadrature encoder inputs and two timer outputs; supports synchronous AI/AO/DIO, external clock and triggering.
Models and software: available as standard (screw-terminal) and OEM board-only (header) versions, USB-powered with no external supply; supplied with DAQami, TracerDAQ Pro and DASYLab, supporting Windows/Linux/Android.
Technical details & configuration
Source: MCC (Measurement Computing), now part of Digilent. Specifications have been checked against the source description and official MCC/Digilent manuals. The USB-1808 runs at 50 kS/s/ch while the USB-1808X is the 200 kS/s/ch high-speed model; -OEM versions are board-only (header interface), while standard models use screw terminals. Confirm exact models and availability with the Digilent official site.
| Item | Published information | Source |
|---|---|---|
| Analog inputs | 8 simultaneous inputs (per-channel software-selectable 8SE/8DIFF) | [1] |
| Resolution | 18-bit | [1] |
| Input ranges | ±10 V, ±5 V, 0–10 V, 0–5 V (per-channel selectable) | [1] |
| Sample rate | Up to 200 kS/s/ch (X) / 50 kS/s/ch (standard) | [1] |
| USB-1808 | 18-bit, 8 simultaneous inputs, 50 kS/s/ch, 2AO/4DIO, screw terminals | [1] |
| USB-1808X | As USB-1808, 200 kS/s/ch sampling, 500 kS/s/ch AO | [1] |
| USB-1808-OEM / 1808X-OEM | Board-only versions with header interface, same rates as standard models | [1] |
Provide the required model (USB-1808 / 1808X, standard or OEM board), channel count and differential/single-ended configuration, sample rate and resolution requirements, analog output needs, digital I/O, counter and quadrature encoder needs, whether external clock/digital trigger/pattern trigger is needed, and software (DAQami/DASYLab/TracerDAQ Pro) and operating system needs.
Questions before you start
Do the listed values apply to every configuration?
Source: MCC (Measurement Computing), now part of Digilent. Specifications have been checked against the source description and official MCC/Digilent manuals. The USB-1808 runs at 50 kS/s/ch while the USB-1808X is the 200 kS/s/ch high-speed model; -OEM versions are board-only (header interface), while standard models use screw terminals. Confirm exact models and availability with the Digilent official site.
What should I prepare for a technical discussion?
Provide the required model (USB-1808 / 1808X, standard or OEM board), channel count and differential/single-ended configuration, sample rate and resolution requirements, analog output needs, digital I/O, counter and quadrature encoder needs, whether external clock/digital trigger/pattern trigger is needed, and software (DAQami/DASYLab/TracerDAQ Pro) and operating system needs.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.