Low-to-mid channel multifunction acquisition: 8 SE/4 DIFF analog inputs combining analog I/O, digital I/O and counters, ideal for low-to-mid channel systems.
USB-1208FS-Plus/LS/1408FS-Plus Series Data Acquisition Card
The MCC USB-1208FS-Plus/LS/1408FS-Plus series are low-to-mid channel multifunction USB DAQ devices: 8 SE/4 DIFF analog inputs with 12- or 14-bit resolution at 1.2 kS/s to 50 kS/s, two analog outputs, 16 digital I/O lines and one 32-bit counter. Board-only OEM versions are available for embedded applications.
What this solution covers
Flexible resolution and sampling: 12- or 14-bit resolution models with sample rates from 1.2 kS/s to 50 kS/s, plus 2 analog outputs and one 32-bit counter.
Rich software ecosystem: DAQami and TracerDAQ for acquisition, display and signal generation; a Universal Library supporting Visual C++/C#/VB.NET, ULx for NI LabVIEW and the open-source DAQFlex framework; board-only OEM versions available.
Technical details & configuration
Source: MCC (Measurement Computing), now part of Digilent. Specifications below have been checked against the source USB-1208FS-Plus/LS/1408FS-Plus description and the official specification; the three models differ in resolution and sample rate, so confirm the exact model and version for the project.
| Item | Published information | Source |
|---|---|---|
| USB-1208FS-Plus | 8 SE/4 DIFF, 12-bit, up to 50 kS/s, 2 analog outputs, 16 DIO, one 32-bit counter | [1] |
| USB-1208LS | 8 SE/4 DIFF, 12-bit, low-speed model, 2 analog outputs, 16 DIO, one 32-bit counter | [1] |
| USB-1408FS-Plus | 8 SE/4 DIFF, 14-bit, up to 50 kS/s, 2 analog outputs, 16 DIO, one 32-bit counter | [1] |
| Software & drivers | DAQami (paid), TracerDAQ; Universal Library for Visual C++/C#/VB.NET, ULx for NI LabVIEW, open-source DAQFlex | [1] |
| OEM version | Board-only version available for embedded applications | [1] |
Provide the required model (USB-1208FS-Plus / 1208LS / 1408FS-Plus), resolution and sample rate, analog input/output channel count, digital I/O and counter application, whether a board-only OEM version is needed, and operating system and software requirements (DAQami, TracerDAQ, DAQFlex, LabVIEW, etc.). Current specifications follow the Digilent official site.
Questions before you start
Do the listed values apply to every configuration?
Source: MCC (Measurement Computing), now part of Digilent. Specifications below have been checked against the source USB-1208FS-Plus/LS/1408FS-Plus description and the official specification; the three models differ in resolution and sample rate, so confirm the exact model and version for the project.
What should I prepare for a technical discussion?
Provide the required model (USB-1208FS-Plus / 1208LS / 1408FS-Plus), resolution and sample rate, analog input/output channel count, digital I/O and counter application, whether a board-only OEM version is needed, and operating system and software requirements (DAQami, TracerDAQ, DAQFlex, LabVIEW, etc.). Current specifications follow the Digilent official site.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.