Power-Frequency Impulse High-Current Test System

A power-frequency high-current system for switch short-circuit withstand tests, outputting 600 A–20 kA (rms) at 240 V / 420 V with ±5% error. Compliant with IEC 62055-31 and ANSI C12.1, with power factor per IEC 61008-1.

View technical details
Power-frequency impulse high-current test system: control cabinets and test control / data logging software interface
CAPABILITIES

What this solution covers

01

Clear purpose: verifies switch short-circuit withstand performance, widely used in electrical manufacturing, power operation, research institutes and universities.

02

High-current output: 600 A–20 kA (rms) power-frequency short-circuit current, 240 V / 420 V test voltage, with ±5% error for both current and voltage.

03

Standards compliance: meets IEC 62055-31 (Uc2/Uc3/Uc4) and ANSI C12.1, with power factor per IEC 61008-1 Table 16.

TECHNICAL REFERENCE

Technical details & configuration

Source: domestic high-voltage test equipment (distributed by Linkall). The specifications below are taken from the manufacturer's power-frequency impulse high-current test system page; the specific current class, test voltage and supply configuration remain subject to project confirmation. See the notes in each row for the applicable scope.

Configuration limits are stated per row.
ItemPublished informationSource
ApplicationMainly for switch short-circuit withstand tests, widely used in electrical manufacturing, power operation departments, research institutes and universities[1]
Applicable StandardsThe high-current short-circuit test system meets IEC 62055-31 Uc2, Uc3, Uc4 and ANSI C12.1 requirements[1]
Max Output CurrentMax 20 kA power-frequency short-circuit current[1]
Short-Circuit Test Current Range600 A – 20 kA (rms)[1]
Test Voltage Class240V、420V[1]
Test ErrorTest current error: ±5%; test voltage error: ±5%; current ≤±2%; voltage ≤±1.5%[1]
Power Factor600 A – 20 kA complies with IEC 61008-1 Table 16, deviation ≤-0.05[1]
Confirm before selection

Provide the DUT type (switch, circuit breaker, electricity meter, etc.), short-circuit test current (600 A–20 kA rms), test voltage class (240 V or 420 V), power factor requirement, test duration and operation sequence, plus control system and calibration needs. Confirm with the manufacturer.

FAQ

Questions before you start

Do the listed values apply to every configuration?

Source: domestic high-voltage test equipment (distributed by Linkall). The specifications below are taken from the manufacturer's power-frequency impulse high-current test system page; the specific current class, test voltage and supply configuration remain subject to project confirmation. See the notes in each row for the applicable scope.

What should I prepare for a technical discussion?

Provide the DUT type (switch, circuit breaker, electricity meter, etc.), short-circuit test current (600 A–20 kA rms), test voltage class (240 V or 420 V), power factor requirement, test duration and operation sequence, plus control system and calibration needs. Confirm with the manufacturer.

How do I request documentation?

Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.

Sources · checked 2026-11-25
  1. 凌茂:工频冲击大电流试验系统 / LinkAll: Power Frequency High-Current Impulse Test SystemLegacy website reference

Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.

LinkAll

Customer service

For product enquiries and technical support, please contact us:

Telephone
021-52831768 / 52833853
Email
linkall@inlinkall.com