Shanghai Lingmao Electronic Science and Technology Co., Ltd.
OPSENS

Opsens OTP-P Fiber Optic Temperature Sensor

The Opsens OTP-P (Canada) is a rugged WLPI fiber optic temperature sensor based on monocrystalline birefringence with no thermal creeping or aging. Housed in a stainless-steel thermowell, it covers -40 °C to +250 °C with ±1.0 °C accuracy, is immune to EMI/RFI and microwave, and is compatible with WLPI signal conditioners.

View technical details
Opsens OTP-P fiber optic temperature sensor: stainless-steel probe photo, benefit and application lists, and specification table
CAPABILITIES

What this solution covers

01

WLPI monocrystalline birefringence: temperature-dependent birefringence of a selected crystal as the transduction mechanism; pure monocrystalline material with no thermal creeping or aging, industry-leading performance.

02

Rugged packaging: stainless-steel thermowell (ceramic or other materials optional), suited to demanding applications and rough handling, with long-term robustness.

03

Harsh-environment ready: outstanding repeatability under high EM/RF/microwave fields, high voltage and rapid temperature cycling, ±1.0 °C accuracy, intrinsically safe, compatible with WLPI conditioners and OEM customization.

TECHNICAL REFERENCE

Technical details & configuration

Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OTP-P fiber optic temperature sensor page; the specific range (standard -40 °C to +250 °C), accuracy class, thermowell material, fiber length and connector configuration remain subject to project confirmation. See the notes in each row for the applicable scope.

Configuration limits are stated per row.
ItemPublished informationSource
Temperature Operating & Calibrated Range-40 °C to +250 °C[1]
Accuracy±1.0 °C @ ±3.3 sigma limit (99.9% confidence level)[1]
Operating Humidity Range0~100%[1]
EMI/RFI SusceptibilityComplete immunity[1]
CalibrationNIST traceable[1]
Cable Length1.5 m standard (other lengths available)[1]
Optical ConnectorSC standard[1]
Signal Conditioner CompatibilityAll Opsens Solutions' WLPI signal conditioners[1]
Confirm before selection

Provide the application, required temperature range, accuracy requirements, thermowell material, fiber length, connector type, sheathing options, plus the matching WLPI signal conditioner and NIST-traceable calibration needs. Confirm with the manufacturer.

FAQ

Questions before you start

Do the listed values apply to every configuration?

Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OTP-P fiber optic temperature sensor page; the specific range (standard -40 °C to +250 °C), accuracy class, thermowell material, fiber length and connector configuration remain subject to project confirmation. See the notes in each row for the applicable scope.

What should I prepare for a technical discussion?

Provide the application, required temperature range, accuracy requirements, thermowell material, fiber length, connector type, sheathing options, plus the matching WLPI signal conditioner and NIST-traceable calibration needs. Confirm with the manufacturer.

How do I request documentation?

Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.

Sources · checked 2026-11-26
  1. Opsens 官网 OTP-P 产品页

Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.