WLPI monocrystalline birefringence: temperature-dependent birefringence of a selected crystal as the transduction mechanism; pure monocrystalline material shows no thermal creeping or aging, with industry-leading performance.
Opsens OTP-A Fiber Optic Temperature Sensor
The Opsens OTP-A (Canada) is a multi-purpose fiber optic temperature sensor based on WLPI monocrystalline birefringence, with no thermal creeping or aging. It covers -40 °C to +250 °C with ±1.0 °C accuracy and 1.5 s response, is immune to EMI/RFI and microwave, and is compatible with WLPI signal conditioners.
What this solution covers
Harsh-environment ready: fully immune to EMI/RFI, RF, MR and microwave, withstands high voltage and rapid temperature cycling, with outstanding repeatability and intrinsic safety.
Multi-purpose and customizable: -40 °C to +250 °C range, ±1.0 °C accuracy, 1.5 s response, compatible with WLPI conditioners, various cables and sheathings, with OEM options.
Technical details & configuration
Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OTP-A fiber optic temperature sensor page; the specific range (standard -40 °C to +250 °C), accuracy class, fiber length and connector configuration remain subject to project confirmation. See the notes in each row for the applicable scope.
| Item | Published information | Source |
|---|---|---|
| Temperature Operating & Calibrated Range | -40 °C to +250 °C | [1] |
| Accuracy | ±1.0 °C @ ±3.3 sigma limit (99.9% confidence level) | [1] |
| Response Time | 1.5 s typical (depends on packaging and measuring conditions) | [1] |
| Operating Humidity Range | 0~100% | [1] |
| EMI/RFI Susceptibility | Complete immunity | [1] |
| Calibration | NIST traceable | [1] |
| Cable Length | 1.5 m standard (other lengths available) | [1] |
| Optical Connector | SC standard | [1] |
Provide the application, required temperature range, accuracy and response-time requirements, fiber length, connector type, sheathing options, environmental humidity conditions, plus the matching WLPI signal conditioner and NIST-traceable calibration needs. Confirm with the manufacturer.
Questions before you start
Do the listed values apply to every configuration?
Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OTP-A fiber optic temperature sensor page; the specific range (standard -40 °C to +250 °C), accuracy class, fiber length and connector configuration remain subject to project confirmation. See the notes in each row for the applicable scope.
What should I prepare for a technical discussion?
Provide the application, required temperature range, accuracy and response-time requirements, fiber length, connector type, sheathing options, environmental humidity conditions, plus the matching WLPI signal conditioner and NIST-traceable calibration needs. Confirm with the manufacturer.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.