Shanghai Lingmao Electronic Science and Technology Co., Ltd.
OPSENS

Opsens OTP-A Fiber Optic Temperature Sensor

The Opsens OTP-A (Canada) is a multi-purpose fiber optic temperature sensor based on WLPI monocrystalline birefringence, with no thermal creeping or aging. It covers -40 °C to +250 °C with ±1.0 °C accuracy and 1.5 s response, is immune to EMI/RFI and microwave, and is compatible with WLPI signal conditioners.

View technical details
Opsens OTP-A fiber optic temperature sensor: multi-purpose probe photo, benefit and application lists, and specification table
CAPABILITIES

What this solution covers

01

WLPI monocrystalline birefringence: temperature-dependent birefringence of a selected crystal as the transduction mechanism; pure monocrystalline material shows no thermal creeping or aging, with industry-leading performance.

02

Harsh-environment ready: fully immune to EMI/RFI, RF, MR and microwave, withstands high voltage and rapid temperature cycling, with outstanding repeatability and intrinsic safety.

03

Multi-purpose and customizable: -40 °C to +250 °C range, ±1.0 °C accuracy, 1.5 s response, compatible with WLPI conditioners, various cables and sheathings, with OEM options.

TECHNICAL REFERENCE

Technical details & configuration

Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OTP-A fiber optic temperature sensor page; the specific range (standard -40 °C to +250 °C), accuracy class, fiber length and connector configuration remain subject to project confirmation. See the notes in each row for the applicable scope.

Configuration limits are stated per row.
ItemPublished informationSource
Temperature Operating & Calibrated Range-40 °C to +250 °C[1]
Accuracy±1.0 °C @ ±3.3 sigma limit (99.9% confidence level)[1]
Response Time1.5 s typical (depends on packaging and measuring conditions)[1]
Operating Humidity Range0~100%[1]
EMI/RFI SusceptibilityComplete immunity[1]
CalibrationNIST traceable[1]
Cable Length1.5 m standard (other lengths available)[1]
Optical ConnectorSC standard[1]
Confirm before selection

Provide the application, required temperature range, accuracy and response-time requirements, fiber length, connector type, sheathing options, environmental humidity conditions, plus the matching WLPI signal conditioner and NIST-traceable calibration needs. Confirm with the manufacturer.

FAQ

Questions before you start

Do the listed values apply to every configuration?

Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OTP-A fiber optic temperature sensor page; the specific range (standard -40 °C to +250 °C), accuracy class, fiber length and connector configuration remain subject to project confirmation. See the notes in each row for the applicable scope.

What should I prepare for a technical discussion?

Provide the application, required temperature range, accuracy and response-time requirements, fiber length, connector type, sheathing options, environmental humidity conditions, plus the matching WLPI signal conditioner and NIST-traceable calibration needs. Confirm with the manufacturer.

How do I request documentation?

Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.

Sources · checked 2026-11-26
  1. Opsens 官网 OTP-A 产品页

Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.

LinkAll

Customer service

For product enquiries and technical support, please contact us:

Telephone
021-52831768 / 52833853
Email
linkall@inlinkall.com