GaAs-bandgap tip sensing: a GaAs crystal at the fiber tip acts as the transducer, industry-leading high performance for tip measurement, intrinsically safe.
Opsens OTG-Q Fiber Optic Temperature Sensor
The Opsens OTG-Q (Canada) is a high-accuracy GaAs fiber optic temperature sensor with a 1.4 mm PFA welded sealed tip suitable for liquid immersion. It covers -40 °C to +250 °C with ±0.8 °C accuracy and 1 s response, is immune to EMI/RFI and microwave, and is compatible with SCBG signal conditioners.
What this solution covers
Welded sealed tip: a welded design in a 1.4 mm OD PFA sheath offers a complete tip seal, best suited to applications involving liquid immersion.
Harsh-environment ready: immune to EMI/RFI and microwave, outstanding repeatability, ±0.8 °C accuracy, compatible with SCBG conditioners, with OEM-type and custom versions.
Technical details & configuration
Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OTG-Q fiber optic temperature sensor page; the specific range (standard -40 °C to +250 °C, other ranges available), accuracy class, fiber length and connector configuration remain subject to project confirmation. See the notes in each row for the applicable scope.
| Item | Published information | Source |
|---|---|---|
| Temperature Operating & Calibrated Range (others available) | -40 °C to +250 °C (other ranges available upon request) | [1] |
| Accuracy | ±0.8 °C or better (total accuracy over full range, including signal conditioner and sensor errors) | [1] |
| Response Time | 1.0 s typical | [1] |
| Operating Humidity Range | 0~100% | [1] |
| EMI/RFI Susceptibility | Complete immunity | [1] |
| Calibration | NIST traceable | [1] |
| Cable Length | 1.5 m standard (other lengths available) | [1] |
| Optical Connector | LCA, ST standard | [1] |
| Signal Conditioner Compatibility | All Opsens Solutions' SCBG signal conditioners | [1] |
Provide the application, required temperature range, accuracy and response-time requirements, fiber length, connector type, sheathing options, plus the matching SCBG signal conditioner and NIST-traceable calibration needs. Confirm with the manufacturer.
Questions before you start
Do the listed values apply to every configuration?
Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OTG-Q fiber optic temperature sensor page; the specific range (standard -40 °C to +250 °C, other ranges available), accuracy class, fiber length and connector configuration remain subject to project confirmation. See the notes in each row for the applicable scope.
What should I prepare for a technical discussion?
Provide the application, required temperature range, accuracy and response-time requirements, fiber length, connector type, sheathing options, plus the matching SCBG signal conditioner and NIST-traceable calibration needs. Confirm with the manufacturer.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.