GaAs-bandgap sensing: a miniature GaAs crystal (0.15 × 0.15 mm) at the fiber tip, in a 0.22 mm OD tube, compact, robust and low-thermal-mass.
Opsens OTG-PM Fiber Optic Temperature Sensor
The Opsens OTG-PM (Canada) is a GaAs fiber optic temperature sensor for power electronics. Its 0.22 mm probe, with retractable ceramic tubing and a holder, pierces silicon gel for precise positioning. It is fast, accurate to ±0.8 °C, immune to EMI/RFI, and compatible with SCBG signal conditioners.
What this solution covers
Retractable with holder: rigid ceramic tubing (Ø0.64 mm) pierces silicon gel for precise positioning; a Teflon-coated curved stainless-steel tube eases visual alignment, and a holder enables quick, precise angle adjustment.
Fast and accurate: millisecond-level response, ±0.8 °C accuracy or better, immune to EMI/RFI, MR and microwave, compatible with SCBG conditioners and available for OEM customization.
Technical details & configuration
Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OTG-PM fiber optic temperature sensor page; the specific range (standard -40 °C to +250 °C, customizable up to 350 °C), accuracy class, fiber length and connector configuration remain subject to project confirmation. See the notes in each row for the applicable scope.
| Item | Published information | Source |
|---|---|---|
| Temperature Operating & Calibrated Range | -40 °C to +250 °C (up to 350 °C, other ranges available) | [1] |
| Accuracy | ±0.8 °C or better (including both signal conditioner and sensor errors) | [1] |
| Operating Humidity Range | 0~100% | [1] |
| MRI/EMI/RFI Susceptibility | Complete immunity | [1] |
| Calibration | NIST traceable | [1] |
| Cable Length | 1.5 m standard (other lengths available) | [1] |
| Optical Connector | LCA, ST standard | [1] |
| Signal Conditioner Compatibility | All Opsens Solutions' GaAs (SCBG) signal conditioners | [1] |
Provide the application, required temperature range, accuracy and response-time requirements, fiber length, connector type, sheathing options, plus the matching SCBG signal conditioner and NIST-traceable calibration needs. Confirm with the manufacturer.
Questions before you start
Do the listed values apply to every configuration?
Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OTG-PM fiber optic temperature sensor page; the specific range (standard -40 °C to +250 °C, customizable up to 350 °C), accuracy class, fiber length and connector configuration remain subject to project confirmation. See the notes in each row for the applicable scope.
What should I prepare for a technical discussion?
Provide the application, required temperature range, accuracy and response-time requirements, fiber length, connector type, sheathing options, plus the matching SCBG signal conditioner and NIST-traceable calibration needs. Confirm with the manufacturer.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.