GaAs-bandgap tip sensing: a GaAs crystal at the fiber tip acts as the transducer, compact and robust for tip/point measurement, intrinsically safe.
Opsens OTG-M Series Fiber Optic Temperature Sensor
The Opsens OTG-M Series (Canada) is a GaAs-bandgap fiber optic temperature sensor family with seven models for miniature tip measurement. Response is from ≤50 ms, accuracy ±0.8 °C, with immunity to EMI/RFI and microwave, intrinsic safety, and compatibility with SCBG signal conditioners.
What this solution covers
Seven models: M220/M360/M420/M600/MPK5/MPK6/MPK8, diameters 0.22–0.81 mm, polyimide/glass/PEEK tubes, response from ≤50 ms.
Harsh-environment ready: immune to EMI/RFI and microwave, ±0.8 °C accuracy with outstanding repeatability, compatible with SCBG conditioners, with OEM customization.
Technical details & configuration
Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OTG-M series page; model-specific differences (response time, diameter, tip tube material) are listed per row, while common specifications (temperature range, accuracy, connector, etc.) follow the manufacturer's data. The specific range, accuracy class, fiber length and connector configuration remain subject to project confirmation.
| Item | Published information | Source |
|---|---|---|
| OTG-M220 | Response time: ≤50 ms; sensor diameter: ≤0.220 mm; tip tube material: polyimide | [1] |
| OTG-M360 | Response time: <100 ms; sensor diameter: 0.360 mm; tip tube material: glass | [1] |
| OTG-M420 | Response time: <200 ms; sensor diameter: 0.420 mm; tip tube material: polyimide | [1] |
| OTG-M600 | Response time: <200 ms; sensor diameter: 0.600 mm; tip tube material: polyimide | [1] |
| OTG-MPK5 | Response time: <225 ms; sensor diameter: 0.510 mm; tip tube material: PEEK | [1] |
| OTG-MPK6 | Response time: <225 ms; sensor diameter: 0.600 mm; tip tube material: PEEK | [1] |
| OTG-MPK8 | Response time: <500 ms; sensor diameter: 0.810 mm; tip tube material: PEEK | [1] |
Provide the required model, application, accuracy and response-time requirements, probe diameter and tube material, fiber length, connector type, sheathing options, plus the matching SCBG signal conditioner and NIST-traceable calibration needs. Confirm with the manufacturer.
Questions before you start
Do the listed values apply to every configuration?
Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OTG-M series page; model-specific differences (response time, diameter, tip tube material) are listed per row, while common specifications (temperature range, accuracy, connector, etc.) follow the manufacturer's data. The specific range, accuracy class, fiber length and connector configuration remain subject to project confirmation.
What should I prepare for a technical discussion?
Provide the required model, application, accuracy and response-time requirements, probe diameter and tube material, fiber length, connector type, sheathing options, plus the matching SCBG signal conditioner and NIST-traceable calibration needs. Confirm with the manufacturer.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.