GaAs-bandgap sensing: a tiny GaAs crystal at the fiber tip acts as the transducer, only 0.22 mm in diameter, compact, robust and low-thermal-mass, intrinsically safe.
Opsens OTG-I220 Fiber Optic Temperature Sensor
The Opsens OTG-I220 (Canada) is a GaAs fiber optic temperature sensor for power electronics, with a 0.22 mm probe, <35 ms response and ±0.8 °C accuracy. Its smart retractable design pierces silicon gel, it is immune to EMI/RFI, and it is compatible with SCBG signal conditioners.
What this solution covers
Smart retractable design: an optional TT polyimide telescoping tube protects the probe and lets it pierce silicon gel to reach a precise spot on a die or circuit board, without limiting flexibility.
Fast and accurate: <35 ms response, ±0.8 °C accuracy or better, 0.05 °C resolution, immune to EMI/RFI, compatible with all SCBG signal conditioners.
Technical details & configuration
Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OTG-I220 fiber optic temperature sensor page; the specific range (standard -40 °C to +250 °C, customizable up to 350 °C), accuracy class, fiber length and connector configuration remain subject to project confirmation. See the notes in each row for the applicable scope.
| Item | Published information | Source |
|---|---|---|
| emperature Operating & Calibrated Range | -40 °C to +250 °C (up to 350 °C, other ranges available) | [1] |
| Resolution | 0.05℃ | [1] |
| Accuracy | ±0.8 °C or better (total accuracy over operating range, including signal conditioner and sensor errors) | [1] |
| Response Time | <35 ms (typical) | [1] |
| Operating Humidity Range | 0~100% | [1] |
| EMI/RFI Susceptibility | Fully shielded | [1] |
| Calibration | NIST traceable | [1] |
| Cable Length | 1.5 m standard (other lengths available) | [1] |
| Optical Connector | LCA, ST standard | [1] |
| Cable Sheathing | Teflon™ PTFE (other materials available) | [1] |
| Signal Conditioner Compatibility | All Opsens SCBG signal conditioners | [1] |
Provide the application, required temperature range, accuracy and response-time requirements, fiber length, connector type, sheathing options, plus the matching SCBG signal conditioner and NIST-traceable calibration needs. Confirm with the manufacturer.
Questions before you start
Do the listed values apply to every configuration?
Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OTG-I220 fiber optic temperature sensor page; the specific range (standard -40 °C to +250 °C, customizable up to 350 °C), accuracy class, fiber length and connector configuration remain subject to project confirmation. See the notes in each row for the applicable scope.
What should I prepare for a technical discussion?
Provide the application, required temperature range, accuracy and response-time requirements, fiber length, connector type, sheathing options, plus the matching SCBG signal conditioner and NIST-traceable calibration needs. Confirm with the manufacturer.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.