GaAs-bandgap sensing: a tiny GaAs crystal at the fiber tip acts as the temperature transducer, compact and robust for tip/point measurement, intrinsically safe.
Opsens OTG-F Fiber Optic Temperature Sensor
The Opsens OTG-F (Canada) is a GaAs-bandgap fiber optic temperature sensor with a 5 ms response for dynamic temperature measurement, intrinsically safe. It covers -40 °C to +250 °C with ±0.8 °C accuracy and 0.05 °C resolution, is immune to EMI/RFI, and is compatible with SCBG signal conditioners.
What this solution covers
Fast response: about 5 ms response time, designed for dynamic temperature monitoring and rapidly changing conditions, suitable for chip-level and transient measurement.
Harsh-environment ready: fully immune to EMI/RFI, RF and microwave interference, with outstanding repeatability in high-field EM, high-voltage, nuclear and hazardous environments, compatible with all SCBG signal conditioners.
Technical details & configuration
Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OTG-F fiber optic temperature sensor page; the specific range (standard -40 °C to +250 °C or customized), accuracy class, fiber length and connector configuration remain subject to project confirmation. See the notes in each row for the applicable scope.
| Item | Published information | Source |
|---|---|---|
| Operating Temperature | -40 °C to +250 °C (others customizable) | [1] |
| Resolution | 0.05℃ | [1] |
| Accuracy | ±0.8 °C or better | [1] |
| Response Tim | 5ms | [1] |
| Operating Humidity | 0%~100% | [1] |
| Calibration | NIST traceable | [1] |
| Fiber Length | 1.5 m standard (other lengths available) | [1] |
| Optical Connector | ST | [1] |
| Fiber Packaging | Polytetrafluoroethylene | [1] |
| Signal Conditioner Compatibility | All Opsens SCBG signal conditioners | [1] |
Provide the application (dynamic measurement / high voltage / microwave / sterilization / nuclear, etc.), required temperature range (-40 °C to +250 °C or custom), accuracy and response-time (5 ms standard) requirements, fiber length (1.5 m standard or custom), connector type (ST), packaging and sheathing options (PTFE/PVC), plus the matching SCBG signal conditioner and NIST-traceable calibration needs. Confirm with the manufacturer.
Questions before you start
Do the listed values apply to every configuration?
Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OTG-F fiber optic temperature sensor page; the specific range (standard -40 °C to +250 °C or customized), accuracy class, fiber length and connector configuration remain subject to project confirmation. See the notes in each row for the applicable scope.
What should I prepare for a technical discussion?
Provide the application (dynamic measurement / high voltage / microwave / sterilization / nuclear, etc.), required temperature range (-40 °C to +250 °C or custom), accuracy and response-time (5 ms standard) requirements, fiber length (1.5 m standard or custom), connector type (ST), packaging and sheathing options (PTFE/PVC), plus the matching SCBG signal conditioner and NIST-traceable calibration needs. Confirm with the manufacturer.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.