MEMS stainless-steel sealed design: robust fully sealed stainless-steel housing and diaphragm, submersible and suited to harsh groundwater, geotechnical and chemical environments.
Opsens OPP-C Fiber Optic Pressure Sensor
The Opsens OPP-C (Canada) is a MEMS-based fiber optic pressure sensor with a fully sealed stainless-steel housing for submersible use in harsh environments. It offers a 50–1000 PSI range, ±0.2% F.S. accuracy, fiber up to 3 km, immunity to EMI/RFI and lightning, and compatibility with WLPI signal conditioners.
What this solution covers
Intrinsically safe and maintenance-free: no drift over time for reliable long-term results, fully immune to EMI/RFI, lightning and high-voltage interference.
Long-distance and customizable: fiber readout up to 3 km away, compatible with all Opsens WLPI signal conditioners, with an optional OPP-CT integrated temperature sensor.
Technical details & configuration
Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OPP-C fiber optic pressure sensor page; the specific range, accuracy class, housing dimensions and cable/connector configuration remain subject to project confirmation. See the notes in each row for the applicable scope.
| Item | Published information | Source |
|---|---|---|
| Measurement Range | 50~1000 PSI (others customizable) | [1] |
| Accuracy | ±0.2%F.S. | [1] |
| Resolution | <0.02%F.S. | [1] |
| Operating Temperature | -20 °C to +85 °C (others customizable) | [1] |
| Thermal Coefficient of Zero | <0.03%F.S./℃ | [1] |
| Proof Pressure | 200%F.S. | [1] |
| Housing Material | Stainless steel | [1] |
| Housing Dimensions | 123~220mm × 9.5mm OD | [1] |
| Weight | Customizable | [1] |
| Optical Connector | SCA / SC (customizable) | [1] |
| Signal Conditioner Compatibility | All Opsens WLPI signal conditioners | [1] |
Provide the measured medium and application (groundwater / geotechnical / chemical, etc.), required range (50–1000 PSI or custom), accuracy and resolution requirements, operating temperature, fiber length and connector type (SCA/SC or other), whether the OPP-CT integrated temperature sensor is needed, plus the matching WLPI signal conditioner and calibration needs. Confirm with the manufacturer.
Questions before you start
Do the listed values apply to every configuration?
Source: Opsens (Canada), distributed by Linkall. The specifications below are taken from the manufacturer's OPP-C fiber optic pressure sensor page; the specific range, accuracy class, housing dimensions and cable/connector configuration remain subject to project confirmation. See the notes in each row for the applicable scope.
What should I prepare for a technical discussion?
Provide the measured medium and application (groundwater / geotechnical / chemical, etc.), required range (50–1000 PSI or custom), accuracy and resolution requirements, operating temperature, fiber length and connector type (SCA/SC or other), whether the OPP-CT integrated temperature sensor is needed, plus the matching WLPI signal conditioner and calibration needs. Confirm with the manufacturer.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.