Magnetic Probe (MP) scanning method: the near-field scanning method first developed by NEC; its probe specifications were adopted by IEC as the international standard IEC 61967-6, complied with by both the 4EM200 and 4EM500.
Board-Level EMC Scanning and Analysis System
Combines NEC EMIStream software with 4EM200/4EM500 scanners for PCB-level EMC analysis. EMIStream runs design-rule and plane-resonance checks; the scanners apply the magnetic-probe (MP) method (IEC 61967-6) to map near-field noise and locate sources, cutting rework and cost.
What this solution covers
EMIStream design-stage analysis: EMI rule checks and power/ground-plane resonance analysis can be performed at the early PCB design stage without specialized EMI knowledge; functions include layout/routing rule checks, ground-plane resonance simulation, far-field emission simulation, ESD rule checks and PI analysis.
Graphical noise visualization: magnetic-field scan results are overlaid on the board layout and shown as a color heat map, locating noise sources and problem points (components, traces, pins) on the measurement surface as well as on inner and back layers.
Technical details & configuration
Source: NEC (Nippon Electric Company). Values have been checked against the official NEC EMIStream documentation and 4EM200/4EM500 technical data. Confirm software editions, probe configuration, scanning range and supply configuration for the project.
| Item | Published information | Source |
|---|---|---|
| System composition | EMIStream simulation software + 4EM200/4EM500 EMC scanner + magnetic-field probes | [1] |
| Test method | Magnetic Probe (MP) scanning method, compliant with IEC 61967-6 | [1] |
| 4EM200 measuring range | X/Y/Z = 200×200×100 mm, θ = 0/90° (2 angles); step size 0.1 mm | [1] |
| 4EM500 measuring range | X/Y/Z = 500×500×210 mm, θ = -90° to +90°; step size 0.01 mm | [1] |
| Control interface | USB; 4EM200 power supply AC 100–240 V, 50/60 Hz | [1] |
Provide the PCB size and layer count, the noise/resonance frequency range to be analyzed, the target standard (if any), required scanning resolution and available measuring instruments. A general scanning range does not demonstrate compliance over the entire frequency range.
Questions before you start
Do the listed values apply to every configuration?
Source: NEC (Nippon Electric Company). Values have been checked against the official NEC EMIStream documentation and 4EM200/4EM500 technical data. Confirm software editions, probe configuration, scanning range and supply configuration for the project.
What should I prepare for a technical discussion?
Provide the PCB size and layer count, the noise/resonance frequency range to be analyzed, the target standard (if any), required scanning resolution and available measuring instruments. A general scanning range does not demonstrate compliance over the entire frequency range.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.