Wide frequency coverage: 100 kHz to 20 GHz across LF/RF/XF/SX/MFA families, with both H-field and E-field probes.
Langer Near-Field Probes (LF / RF / XF / SX / MFA Probe Sets)
Langer near-field probes locate electromagnetic interference sources on electronic assemblies during development, covering 100 kHz to 20 GHz. Passive LF/RF/XF/SX and active MFA families are offered in ready-made sets for magnetic- and electric-field measurements, connecting to a 50 Ω spectrum analyzer or oscilloscope input.
What this solution covers
Step-by-step localization: large probes for coarse far-field scans, small high-resolution probes to pinpoint IC pins, traces and components.
Easy measurement: connect to a 50 Ω spectrum analyzer or oscilloscope input; active MFA probes add an integrated amplifier for higher sensitivity and resolution.
Technical details & configuration
Source: Langer EMV-Technik (Germany). The source page lists 11 probe sets with delivery contents in a long image; this compilation follows it and cross-checks model names and frequency ranges against the official product pages. Where the source and official site differ on frequency labels, the manufacturer's data prevails.
| Item | Published information | Source |
|---|---|---|
| LF1 set | Frequency range: 100 kHz–50 MHz; Type: four shielded passive H-field probes; Set: LF-R400, LF-B3, LF-U2.5, LF-U5 H-field probes + SMB-BNC 1 m cable + Case 4+; | [1] |
| RF1 set | Frequency range: 30 MHz–3 GHz; Type: four passive probes (H-field + E-field); Set: RF-K7-4, RF-R3-2, RF-U2.5-2 H-field probes + RF-E10 E-field probe + SMB-BNC 1 m cable + Case 4; | [1] |
| RF2 set | Frequency range: 30 MHz–3 GHz; Type: four passive H-field probes; Set: RF-R400-1, RF-R50-1, RF-U5-2, RF-B3-2 H-field probes + SMB-BNC 1 m cable + Case 4+; | [1] |
| RF3 mini set | Frequency range: 30 MHz–3 GHz; Type: two passive mini H-field probes, resolution <1 mm; Set: RF-B0.3-3, RF-R0.3-3 mini H-field probes + SMB-BNC 1 m cable + Case 4; | [1] |
| RF4-E set | Frequency range: 30 MHz–3 GHz; Type: two passive E-field probes; Set: RF-E02 (electrode approx. 2 cm × 5 cm), RF-E05 (electrode approx. 0.5 mm) E-field probes + SMB-BNC 1 m cable + Case 2; | [1] |
| RF6 set | Frequency range: 30 MHz–3 GHz; Type: two passive H-field + two passive E-field probes; Set: RF-R50-1, RF-B3-2 H-field probes + RF-E02, RF-E10 E-field probes + SMB-BNC 1 m cable + HZ-15 Case; | [1] |
| XF1 set | Frequency range: 30 MHz–6 GHz; Type: four passive H-field + one passive E-field probe; Set: XF-B3-1, XF-R3-1, XF-R400-1, XF-U2.5-1 H-field probes + XF-E10 E-field probe + SMA-SMA 1 m cable + quick guide + Case 5; | [1] |
| SX1 set | Frequency range: 1 GHz–10 GHz; Type: passive near-field probe set (E-field + H-field); Set: SX-E03 E-field probe, SX-B3-1 and SX-R3-1 H-field probes + SMA-SMA 1 m cable + Case 4; | [1] |
| SX-R 20-1 set | Frequency range: 1 GHz–20 GHz; Type: single passive H-field probe set; Set: SX-R 20-1 H-field probe + SMA-SMA 1 m cable + Case 4; | [1] |
| MFA 01 set | Frequency range: 1 MHz–6 GHz;Set: MFA-R0.2-6, MFA-K0.1-12 micro probes (100 MHz–6 GHz) + MFA-R0.2-75 (1 MHz–6 GHz) + BT706 bias tee + SMA-SMA 1 m cable + NT FRI EU supply + MFA case + MFA acc; | [1] |
| MFA 02 set | Frequency range: 1 MHz–1 GHz;Set: MFA-R0.2-75 (1 MHz–6 GHz), MFA-K0.1-30 (1 MHz–1 GHz) micro probes + BT706 bias tee + SMA-SMA 1 m cable + NT FRI EU supply + MFA acc + MFA case; | [1] |
Provide the frequency range of interest (low frequency / RF / microwave), whether magnetic or electric fields are to be measured, probe size and resolution requirements (e.g. IC pins, SMD 0603-0201, conducting paths), whether active MFA micro probes and bias-tee power are needed, the connector type (SMB / SMA) and the required set configuration. Confirm with the manufacturer. Detail Features
Questions before you start
Do the listed values apply to every configuration?
Source: Langer EMV-Technik (Germany). The source page lists 11 probe sets with delivery contents in a long image; this compilation follows it and cross-checks model names and frequency ranges against the official product pages. Where the source and official site differ on frequency labels, the manufacturer's data prevails.
What should I prepare for a technical discussion?
Provide the frequency range of interest (low frequency / RF / microwave), whether magnetic or electric fields are to be measured, probe size and resolution requirements (e.g. IC pins, SMD 0603-0201, conducting paths), whether active MFA micro probes and bias-tee power are needed, the connector type (SMB / SMA) and the required set configuration. Confirm with the manufacturer. Detail Features
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.