Shanghai Lingmao Electronic Science and Technology Co., Ltd.
Langer

Langer Near-Field Probes (LF / RF / XF / SX / MFA Probe Sets)

Langer near-field probes locate electromagnetic interference sources on electronic assemblies during development, covering 100 kHz to 20 GHz. Passive LF/RF/XF/SX and active MFA families are offered in ready-made sets for magnetic- and electric-field measurements, connecting to a 50 Ω spectrum analyzer or oscilloscope input.

View technical details
Langer near-field probe sets: LF1, RF1, RF2, RF3 mini, RF4-E, RF6, XF1, SX1, SX-R 20-1, MFA 01 and MFA 02 with their probe cases
CAPABILITIES

What this solution covers

01

Wide frequency coverage: 100 kHz to 20 GHz across LF/RF/XF/SX/MFA families, with both H-field and E-field probes.

02

Step-by-step localization: large probes for coarse far-field scans, small high-resolution probes to pinpoint IC pins, traces and components.

03

Easy measurement: connect to a 50 Ω spectrum analyzer or oscilloscope input; active MFA probes add an integrated amplifier for higher sensitivity and resolution.

TECHNICAL REFERENCE

Technical details & configuration

Source: Langer EMV-Technik (Germany). The source page lists 11 probe sets with delivery contents in a long image; this compilation follows it and cross-checks model names and frequency ranges against the official product pages. Where the source and official site differ on frequency labels, the manufacturer's data prevails.

Configuration limits are stated per row.
ItemPublished informationSource
LF1 setFrequency range: 100 kHz–50 MHz; Type: four shielded passive H-field probes; Set: LF-R400, LF-B3, LF-U2.5, LF-U5 H-field probes + SMB-BNC 1 m cable + Case 4+; [1]
RF1 setFrequency range: 30 MHz–3 GHz; Type: four passive probes (H-field + E-field); Set: RF-K7-4, RF-R3-2, RF-U2.5-2 H-field probes + RF-E10 E-field probe + SMB-BNC 1 m cable + Case 4; [1]
RF2 setFrequency range: 30 MHz–3 GHz; Type: four passive H-field probes; Set: RF-R400-1, RF-R50-1, RF-U5-2, RF-B3-2 H-field probes + SMB-BNC 1 m cable + Case 4+; [1]
RF3 mini setFrequency range: 30 MHz–3 GHz; Type: two passive mini H-field probes, resolution <1 mm; Set: RF-B0.3-3, RF-R0.3-3 mini H-field probes + SMB-BNC 1 m cable + Case 4; [1]
RF4-E setFrequency range: 30 MHz–3 GHz; Type: two passive E-field probes; Set: RF-E02 (electrode approx. 2 cm × 5 cm), RF-E05 (electrode approx. 0.5 mm) E-field probes + SMB-BNC 1 m cable + Case 2; [1]
RF6 setFrequency range: 30 MHz–3 GHz; Type: two passive H-field + two passive E-field probes; Set: RF-R50-1, RF-B3-2 H-field probes + RF-E02, RF-E10 E-field probes + SMB-BNC 1 m cable + HZ-15 Case; [1]
XF1 setFrequency range: 30 MHz–6 GHz; Type: four passive H-field + one passive E-field probe; Set: XF-B3-1, XF-R3-1, XF-R400-1, XF-U2.5-1 H-field probes + XF-E10 E-field probe + SMA-SMA 1 m cable + quick guide + Case 5;[1]
SX1 setFrequency range: 1 GHz–10 GHz; Type: passive near-field probe set (E-field + H-field); Set: SX-E03 E-field probe, SX-B3-1 and SX-R3-1 H-field probes + SMA-SMA 1 m cable + Case 4; [1]
SX-R 20-1 setFrequency range: 1 GHz–20 GHz; Type: single passive H-field probe set; Set: SX-R 20-1 H-field probe + SMA-SMA 1 m cable + Case 4; [1]
MFA 01 set Frequency range: 1 MHz–6 GHz;Set: MFA-R0.2-6, MFA-K0.1-12 micro probes (100 MHz–6 GHz) + MFA-R0.2-75 (1 MHz–6 GHz) + BT706 bias tee + SMA-SMA 1 m cable + NT FRI EU supply + MFA case + MFA acc; [1]
MFA 02 setFrequency range: 1 MHz–1 GHz;Set: MFA-R0.2-75 (1 MHz–6 GHz), MFA-K0.1-30 (1 MHz–1 GHz) micro probes + BT706 bias tee + SMA-SMA 1 m cable + NT FRI EU supply + MFA acc + MFA case;[1]
Confirm before selection

Provide the frequency range of interest (low frequency / RF / microwave), whether magnetic or electric fields are to be measured, probe size and resolution requirements (e.g. IC pins, SMD 0603-0201, conducting paths), whether active MFA micro probes and bias-tee power are needed, the connector type (SMB / SMA) and the required set configuration. Confirm with the manufacturer. Detail Features

FAQ

Questions before you start

Do the listed values apply to every configuration?

Source: Langer EMV-Technik (Germany). The source page lists 11 probe sets with delivery contents in a long image; this compilation follows it and cross-checks model names and frequency ranges against the official product pages. Where the source and official site differ on frequency labels, the manufacturer's data prevails.

What should I prepare for a technical discussion?

Provide the frequency range of interest (low frequency / RF / microwave), whether magnetic or electric fields are to be measured, probe size and resolution requirements (e.g. IC pins, SMD 0603-0201, conducting paths), whether active MFA micro probes and bias-tee power are needed, the connector type (SMB / SMA) and the required set configuration. Confirm with the manufacturer. Detail Features

How do I request documentation?

Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.

Sources · checked 2026-11-24
  1. Langer 官网近场探头产品页(Near-Field Probes,总览)

Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.

LinkAll

Customer service

For product enquiries and technical support, please contact us:

Telephone
021-52831768 / 52833853
Email
linkall@inlinkall.com