Wideband and low cost: the GTEM cell covers a wide band (DC to microwave) at a fraction of an anechoic chamber's cost, with simple instrumentation, low cost and fast automated testing, offering the best cost-performance for small devices.
GTEM Gigahertz Transverse Electromagnetic (GTEM) Cell System
The GTEM (Gigahertz Transverse Electromagnetic) cell solution offers wide bandwidth (DC to microwave) at low cost for both EMS and EMI testing, especially for small devices. The system comprises a signal source, amplifier, field probe and the cell, with three severity levels (1/3/10 V/m).
What this solution covers
Dual EMS/EMI use: suitable for both electromagnetic radiation susceptibility (EMS/immunity) and emission (EMI) tests; its consistency for RF immunity testing of small devices is widely recognized by test laboratories.
Complete system: composed of a signal generator, power amplifier, antenna, field-strength probe and PC control software, with three severity levels (1/3/10 V/m) for low-radiation, commercial and industrial environments.
Technical details & configuration
Source: Linkall's system EMC test solution. The specifications below are taken from the manufacturer's GTEM cell test solution page; the specific cell model, frequency range, standard compliance and instrument configuration remain subject to project confirmation. See the notes in each row for the applicable scope.
| Item | Published information | Source |
|---|---|---|
| Test Objective | Establish a common basis for evaluating the immunity of electrical and electronic equipment to RF radiated electromagnetic fields | [1] |
| System Composition | The radiated susceptibility (immunity) test system consists of a signal source, power amplifier, field monitor, computer with software and the GTEM cell | [1] |
| Signal Generator | 功率放大器 | [1] |
| Power Amplifier | Mind the bandwidth; maximum output power should match the required test field strength | [1] |
| Antenna & Field Probe | Radiating antenna; field-strength probe for field measurement and recording; automatic measurement additionally requires PC control software | [1] |
| Severity Levels | Three levels: Level 1 1 V/m (low radiation, >1 km from broadcast stations, only low-power mobile phones), Level 2 3 V/m (moderate, typical commercial), Level 3 10 V/m (severe, typical industrial) | [1] |
Provide the product category and dimensions, the standard and frequency range to meet, whether EMS immunity or EMI emission testing is required, the required field strength level, cell size, amplifier power and field probe configuration, plus the automatic control software needs. Confirm with the manufacturer.
Questions before you start
Do the listed values apply to every configuration?
Source: Linkall's system EMC test solution. The specifications below are taken from the manufacturer's GTEM cell test solution page; the specific cell model, frequency range, standard compliance and instrument configuration remain subject to project confirmation. See the notes in each row for the applicable scope.
What should I prepare for a technical discussion?
Provide the product category and dimensions, the standard and frequency range to meet, whether EMS immunity or EMI emission testing is required, the required field strength level, cell size, amplifier power and field probe configuration, plus the automatic control software needs. Confirm with the manufacturer.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
- 凌茂:GTEM 吉赫兹横电磁波室系统 / LinkAll: GTEM Gigahertz Transverse Electromagnetic Wave Chamber SystemLegacy website reference
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.