Simultaneous sampling: a dedicated 24-bit A/D per channel, up to 48 inputs at 10 Hz, freely mixing thermocouples, RTDs and voltage.
DT9874 MEASURpoint Series USB DAQ System
The DT9874 MEASURpoint is an ultra-accurate USB DAQ system from Data Translation: a dedicated 24-bit delta-sigma ADC per channel, up to 48 simultaneous inputs mixing thermocouples, RTDs and voltage (±10/±100/±400 V), at 10 Hz/channel. It offers ±500 V isolation, 8 isolated digital inputs and 8 outputs, auto-calibration, and a 2U half-rack enclosure.
What this solution covers
High isolation and calibration: ISO-Channel ±500 V channel-to-channel and to-earth isolation, power-on auto zero, 2U half-rack enclosure.
USB interface and software: USB connectivity, 8 isolated digital inputs and 8 outputs, with QuickDAQ and IVI-COM driver.
Technical details & configuration
Source: MCC / DT (Data Translation, now part of Digilent). Specifications have been checked against the official MEASURpoint datasheet; the legacy vs. current voltage ranges and isolation, and availability still need to be confirmed per project.
| Item | Published information | Source |
|---|---|---|
| Analog inputs | Up to 48 simultaneous inputs, one A/D per channel | [1] |
| Resolution | 24-bit delta-sigma ADC (per channel) | [1] |
| Measurement type | Thermocouple, RTD, voltage, freely mixable | [1] |
| Sample rate | 10 Hz/channel, simultaneous | [1] |
| Interface | USB (Ethernet LXI version is DT8874) | [1] |
Provide channel count and measurement types (thermocouple/RTD/voltage, mixable), thermocouple type or RTD type (Pt100/500/1000), voltage range, isolation and sample rate requirements, digital I/O application, whether QuickDAQ/IVI-COM drivers are required, and operating system needs. Refer to the Digilent official site for current replacement models.
Questions before you start
Do the listed values apply to every configuration?
Source: MCC / DT (Data Translation, now part of Digilent). Specifications have been checked against the official MEASURpoint datasheet; the legacy vs. current voltage ranges and isolation, and availability still need to be confirmed per project.
What should I prepare for a technical discussion?
Provide channel count and measurement types (thermocouple/RTD/voltage, mixable), thermocouple type or RTD type (Pt100/500/1000), voltage range, isolation and sample rate requirements, digital I/O application, whether QuickDAQ/IVI-COM drivers are required, and operating system needs. Refer to the Digilent official site for current replacement models.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.