Shanghai Lingmao Electronic Science and Technology Co., Ltd.
Data Translation / MCC

DT9874 MEASURpoint Series USB DAQ System

The DT9874 MEASURpoint is an ultra-accurate USB DAQ system from Data Translation: a dedicated 24-bit delta-sigma ADC per channel, up to 48 simultaneous inputs mixing thermocouples, RTDs and voltage (±10/±100/±400 V), at 10 Hz/channel. It offers ±500 V isolation, 8 isolated digital inputs and 8 outputs, auto-calibration, and a 2U half-rack enclosure.

View technical details
DT9874 MEASURpoint USB DAQ system front panel: multi-channel green terminal blocks and USB port
CAPABILITIES

What this solution covers

01

Simultaneous sampling: a dedicated 24-bit A/D per channel, up to 48 inputs at 10 Hz, freely mixing thermocouples, RTDs and voltage.

02

High isolation and calibration: ISO-Channel ±500 V channel-to-channel and to-earth isolation, power-on auto zero, 2U half-rack enclosure.

03

USB interface and software: USB connectivity, 8 isolated digital inputs and 8 outputs, with QuickDAQ and IVI-COM driver.

TECHNICAL REFERENCE

Technical details & configuration

Source: MCC / DT (Data Translation, now part of Digilent). Specifications have been checked against the official MEASURpoint datasheet; the legacy vs. current voltage ranges and isolation, and availability still need to be confirmed per project.

Configuration limits are stated per row.
ItemPublished informationSource
Analog inputsUp to 48 simultaneous inputs, one A/D per channel[1]
Resolution24-bit delta-sigma ADC (per channel)[1]
Measurement typeThermocouple, RTD, voltage, freely mixable[1]
Sample rate10 Hz/channel, simultaneous[1]
InterfaceUSB (Ethernet LXI version is DT8874)[1]
Confirm before selection

Provide channel count and measurement types (thermocouple/RTD/voltage, mixable), thermocouple type or RTD type (Pt100/500/1000), voltage range, isolation and sample rate requirements, digital I/O application, whether QuickDAQ/IVI-COM drivers are required, and operating system needs. Refer to the Digilent official site for current replacement models.

FAQ

Questions before you start

Do the listed values apply to every configuration?

Source: MCC / DT (Data Translation, now part of Digilent). Specifications have been checked against the official MEASURpoint datasheet; the legacy vs. current voltage ranges and isolation, and availability still need to be confirmed per project.

What should I prepare for a technical discussion?

Provide channel count and measurement types (thermocouple/RTD/voltage, mixable), thermocouple type or RTD type (Pt100/500/1000), voltage range, isolation and sample rate requirements, digital I/O application, whether QuickDAQ/IVI-COM drivers are required, and operating system needs. Refer to the Digilent official site for current replacement models.

How do I request documentation?

Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.

Sources · checked 2026-11-24
  1. Digilent 官方 MEASURpoint 数据表 PDF

Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.

LinkAll

Customer service

For product enquiries and technical support, please contact us:

Telephone
021-52831768 / 52833853
Email
linkall@inlinkall.com