Synchronous high-precision acquisition: 8 or 16 simultaneous 24-bit delta-sigma IEPE inputs (software-selectable ±10 V/±1 V) up to 105.469 kHz/channel, 94 dB typical SNR and −110 dB THD, with built-in 4 mA/24 V IEPE current source and software-selectable AC/DC coupling; Sync Bus expands to 64 channels.
DT9857E Series Portable Dynamic Signal Analyzer for Sound and Vibration
The DT9857E is a portable dynamic signal analyzer for sound and vibration, with 8 or 16 simultaneous 24-bit IEPE inputs expandable to 64 channels via Sync Bus, up to 105.4 kS/s/channel and 94 dB SNR, plus two 32-bit analog outputs, 16 digital I/O, a tachometer and counters, all over USB.
What this solution covers
Time-coherent analog output and I/O: two 32-bit D/A outputs (30–216 kHz, ±10 V, fixed level or waveform), 16 digital I/O (8 in / 8 out), one tachometer input (±30 V, 1 MHz) and counter/timer, with all input and output data time-aligned for coherent measurement.
Triggering and software: software, external TTL and analog threshold triggering with pre- and post-trigger sampling; QuickDAQ (FFT/advanced FFT) plus LabVIEW and MATLAB drivers, data export to ME'scopeVES for modal analysis, USB interface and a compact ~1.5 kg design.
Technical details & configuration
Source: MCC (Measurement Computing, now part of Digilent). Specifications have been checked against the official DT9857E datasheet; the power notation, discontinued-model replacement and specific supply configuration still need to be confirmed per project.
| Item | Published information | Source |
|---|---|---|
| Analog inputs | 8/16 simultaneous IEPE inputs (DT9857E-8/-16), expandable to 64 channels | [1] |
| Resolution | 24-bit delta-sigma ADC (one per channel) | [1] |
| 采样率 | 195.3125 Hz to 105.469 kHz/channel | [1] |
| Input ranges | ±10V、±1V | [1] |
| SNR | 94 dB typical | [1] |
| Environment | 0–50 °C, 0–95% RH non-condensing | [1] |
| Power | External 4.75–28 VDC | [1] |
Provide the required model (DT9857E-8 or -16), sensor type (IEPE accelerometer/microphone/voltage) and channel count, sample rate and dynamic range requirements, analog output channel count and range needs, digital I/O and tachometer/counter requirements, whether multi-module synchronization is needed (Sync Bus, up to 64 channels), external trigger needs, and software requirements (QuickDAQ base/FFT/advanced FFT, LabVIEW, MATLAB, ME'scopeVES).
Questions before you start
Do the listed values apply to every configuration?
Source: MCC (Measurement Computing, now part of Digilent). Specifications have been checked against the official DT9857E datasheet; the power notation, discontinued-model replacement and specific supply configuration still need to be confirmed per project.
What should I prepare for a technical discussion?
Provide the required model (DT9857E-8 or -16), sensor type (IEPE accelerometer/microphone/voltage) and channel count, sample rate and dynamic range requirements, analog output channel count and range needs, digital I/O and tachometer/counter requirements, whether multi-module synchronization is needed (Sync Bus, up to 64 channels), external trigger needs, and software requirements (QuickDAQ base/FFT/advanced FFT, LabVIEW, MATLAB, ME'scopeVES).
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.