Dedicated A/D per channel with simultaneous sampling: one 24-bit delta-sigma ADC per channel, up to 48 simultaneous inputs at 10 Hz/channel, freely mixing thermocouples, RTDs and voltage signals.
DT8874 MEASURpoint Series Ethernet DAQ System
The DT8874 MEASURpoint is an ultra-accurate Ethernet DAQ system from Data Translation: a dedicated 24-bit delta-sigma ADC per channel, up to 48 simultaneous inputs mixing thermocouples, RTDs and voltage (±10/±100/±400 V), at 10 Hz/channel. It offers ±500 V isolation, 8 isolated digital inputs and 8 outputs, auto-calibration, and a 2U half-rack enclosure.
What this solution covers
High isolation and auto-calibration: ISO-Channel technology with ±500 V channel-to-channel and to-earth isolation, per-channel cold-junction compensation, power-on auto zero, and a rugged 2U half-rack enclosure.
Ethernet interface and software: LAN (LXI Class C) interface, 8 isolated digital inputs and 8 outputs, free QuickDAQ, IVI-COM driver and SCPI support (DT8874).
Technical details & configuration
Source: Data Translation (DT, noted as "MCC" on the source page; both MCC and DT are now part of Digilent/NI). Specifications have been checked against the source description, the official MEASURpoint datasheet and user manual. Note: the current Digilent MEASURpoint datasheet lists ±10 V/±60 VDC voltage boards and 30 VAC/60 VDC functional isolation (500 Vpk withstand), and offers both USB and Ethernet versions. Confirm exact models, specifications and availability with the manufacturer.
| Item | Published information | Source |
|---|---|---|
| Analog inputs | Up to 48 simultaneous inputs, one A/D per channel | [1] |
| Resolution | 24-bit delta-sigma ADC (per channel) | [1] |
| Measurement type | Thermocouple, RTD, voltage, freely mixable | [1] |
| Voltage range | ±10V/±60VDC | [1] |
| Sample rate | 10 Hz/channel, simultaneous | [1] |
| Interface | Ethernet (LXI Class C) | [1] |
Provide channel count and measurement types (thermocouple/RTD/voltage, mixable), thermocouple type or RTD type (Pt100/500/1000), voltage range, isolation and sample rate requirements, digital I/O application, whether QuickDAQ/IVI-COM/SCPI drivers are required, and operating system needs. Refer to the Digilent official site for current replacement models.
Questions before you start
Do the listed values apply to every configuration?
Source: Data Translation (DT, noted as "MCC" on the source page; both MCC and DT are now part of Digilent/NI). Specifications have been checked against the source description, the official MEASURpoint datasheet and user manual. Note: the current Digilent MEASURpoint datasheet lists ±10 V/±60 VDC voltage boards and 30 VAC/60 VDC functional isolation (500 Vpk withstand), and offers both USB and Ethernet versions. Confirm exact models, specifications and availability with the manufacturer.
What should I prepare for a technical discussion?
Provide channel count and measurement types (thermocouple/RTD/voltage, mixable), thermocouple type or RTD type (Pt100/500/1000), voltage range, isolation and sample rate requirements, digital I/O application, whether QuickDAQ/IVI-COM/SCPI drivers are required, and operating system needs. Refer to the Digilent official site for current replacement models.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.