1. High-precision sound and vibration measurement: 4 simultaneous 24-bit IEPE (ICP) inputs up to 52.7 kHz/channel with a typical 106 dB SNR, built-in 4 mA current source (24 V compliance), AC/DC coupling and ±10 V input range (gains 1/10).
DT8837 Ethernet Dynamic Signal Analyzer
The DT8837 is an Ethernet dynamic signal analyzer with 4 simultaneous 24-bit IEPE inputs up to 52.7 kHz/channel, 106 dB SNR and ±500 V isolation, plus one 24-bit analog output, 4 digital I/O, 2 counters and a tachometer input, with multi-module synchronization.
What this solution covers
ISO-Channel isolation and synchronization: all I/O channels are galvanically isolated ±500 V from each other and the computer, eliminating ground loops and noise; A/D, tachometer, counter and D/A readback channels are sampled simultaneously for precise time correlation.
Expansion and software: a 1U half-rack LXI module stackable up to 16 units (64 channels) via a wired trigger bus; supports TCP/IP Ethernet remote monitoring, with QuickDAQ (free/FFT/advanced FFT) and a .NET signal processing component library.
Technical details & configuration
Source: Data Translation (DT, noted as "Data Translation / MCC" on the source page; both MCC and DT are now part of Digilent). Specifications have been checked against the source description and official datasheet. Confirm availability and replacements with the Digilent official site.
| Item | Published information | Source |
|---|---|---|
| Analog inputs | 4 isolated simultaneous inputs (IEPE or voltage, BNC) | [1] |
| Resolution | 24-bit delta-sigma ADC (one per channel) | [1] |
| Sample rate | Up to 52.7 kHz/channel (52.734 kHz exact) | [1] |
| SNR | 106 dB typical | [1] |
Provide sensor type (IEPE accelerometer/microphone/voltage) and channel count, sample rate and SNR requirements, isolation voltage, whether multi-module synchronization is needed (up to 16 units / 64 channels), analog output and waveform generation needs, digital I/O, counter and tachometer needs, interface (Ethernet/LXI) needs, and software requirements (QuickDAQ editions / .NET signal processing library).
Questions before you start
Do the listed values apply to every configuration?
Source: Data Translation (DT, noted as "Data Translation / MCC" on the source page; both MCC and DT are now part of Digilent). Specifications have been checked against the source description and official datasheet. Confirm availability and replacements with the Digilent official site.
What should I prepare for a technical discussion?
Provide sensor type (IEPE accelerometer/microphone/voltage) and channel count, sample rate and SNR requirements, isolation voltage, whether multi-module synchronization is needed (up to 16 units / 64 channels), analog output and waveform generation needs, digital I/O, counter and tachometer needs, interface (Ethernet/LXI) needs, and software requirements (QuickDAQ editions / .NET signal processing library).
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.