Wide coverage: applies to disturbance voltage/current tests on mains-powered and DC-powered products, including lighting insertion loss tests.
Conducted Emission (CE) Test Solution
Conducted emission (CE) measures disturbance voltage/current on power and signal lines, covering CISPR, EN and GB standards, mostly in the 150 kHz–30 MHz band. It uses a receiver, LISN, artificial hand and probes, with table-top and floor-standing setups; limits vary by standard and product class. Detail Scope Zh
What this solution covers
Comprehensive standards: covers CISPR 22/14-1/13/15/11, EN 55022/14-1/13/15/11, GB 9254/4343/13837/17743 and PART 15/18.
Complete setup: receiver, LISN, artificial hand, voltage/current probes, CDN, discontinuous interference analyzer and insertion loss equipment, per CISPR 16-1-1/2.
Technical details & configuration
Source: Linkall's system EMC test solution. The specifications below are taken from the manufacturer's conducted emission (CE) page; the specific standard version, test setup and instrument configuration remain subject to project confirmation. See the notes in each row for the applicable scope.
| Item | Published information | Source |
|---|---|---|
| Test Standards | CISPR22(ITE)、EN55022、GB9254;CISPR14-1(家电和工具)、EN55014-1、GB4343;CISPR13(AV)、EN55013、GB13837 、CISPR15(灯具)、EN55015、GB17743;CISPR11(ISM)、EN55011;EN61326、EN60601-1-2、EN301489、PART 15、PART 18 | [1] |
| Test Instruments | Receiver, LISN (line impedance stabilization network / AMN artificial mains network), artificial hand, passive voltage probe, current probe (with CDN, capacitive voltage probe), DIA discontinuous interference analyzer, full insertion loss test equipment and PC; DIA per CISPR 16-1-1, other auxiliary equipment per CISPR 16-1-2 | [1] |
| Test Setup | Table-top and floor-standing; table-top device 80 cm from LISN and 40 cm from ground plane; floor-standing distance varies by standard (CISPR 14-1/15: 10 cm ±25%, CISPR 13: up to 12 mm, CISPR 22: up to 15 cm, CISPR 11: unspecified, isolate from ground with insulation) | [1] |
| Auxiliary Equipment Setup | In CISPR 22, auxiliary equipment 10 cm from EUT and interconnecting cables at least 40 cm from ground plane; handheld Class II devices wrapped with artificial hand; in CISPR 15, self-ballasted fluorescent lamps enclosed in an auxiliary conical metal cover | [1] |
| Test Frequency Range | Mostly 150 kHz–30 MHz; CISPR 15 is an exception (disturbance voltage 9 kHz–30 MHz, insertion loss 150 kHz–1,605 kHz) | [1] |
| Test Limits | Limits differ by standard and product classification (Group 1/2, Class A/B) | [1] |
Provide the product category, the standard to meet, power supply, whether signal/control lines are involved, table-top or floor-standing setup, plus disturbance voltage/current limits, discontinuous interference and insertion loss test needs. Confirm with the manufacturer.
Questions before you start
Do the listed values apply to every configuration?
Source: Linkall's system EMC test solution. The specifications below are taken from the manufacturer's conducted emission (CE) page; the specific standard version, test setup and instrument configuration remain subject to project confirmation. See the notes in each row for the applicable scope.
What should I prepare for a technical discussion?
Provide the product category, the standard to meet, power supply, whether signal/control lines are involved, table-top or floor-standing setup, plus disturbance voltage/current limits, discontinuous interference and insertion loss test needs. Confirm with the manufacturer.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
- 凌茂:传导发射 (CE)/ LinkAll: Conducted Emission (CE)Legacy website reference