Site alternative: the anechoic chamber replaces the open area test site for emission measurements, free from climatic constraints and background noise; by absorber arrangement it is divided into semi-anechoic, fully anechoic and modified semi-anechoic types, corresponding to OATS replacement, free-space simulation and additional absorber on the ground plane.
RF Shielding System for Anechoic Chambers
The anechoic chamber serves as an alternative test site to the open area test site, free from climatic constraints and background noise. Classified by absorber arrangement into semi-anechoic, fully anechoic and modified semi-anechoic chambers, and by size into compact, 733-type, small and 3 m/5 m/10 m chambers, with an EMC laboratory design example included.
What this solution covers
Complete size range: from the compact type (approx. 4.6 × 2.5 × 2.75 m) and 733 type (approx. 7 × 3 × 3 m) to 3 m/5 m/10 m chambers (approx. 9 × 6 × 6 m up to 19 × 12 × 9 m), covering in-house pre-testing through to large equipment such as vehicles.
Shielding construction: equipped with a knife-edge elastic shielded door, waveguide window, RF filter, knife-edge cable feed-through panel and insulating ceiling hooks, with an EMC laboratory floor-plan example showing the amplifier room, control room and chamber.
Technical details & configuration
Source: Linkall's system EMC test solution. The specifications below are taken from the RF shielding system for anechoic chambers; the chamber type, dimensions, field uniformity and laboratory layout remain subject to project confirmation. See the notes in each row for the applicable scope.
| Item | Published information | Source |
|---|---|---|
| Semi-Anechoic Chamber | Absorber material covers the other five surfaces except the floor (ground plane); serves as a replacement for the outdoor open area test site | [1] |
| Fully Anechoic Chamber | A shielded room with absorber material on all six inner surfaces including the floor, simulating a free-space propagation environment | [1] |
| Modified Semi-Anechoic Chamber | A semi-anechoic chamber with additional absorber material installed on the ground plane | [1] |
| Compact Predictive Fully Anechoic Chamber | Approx. 4.6 × 2.5 × 2.75 m; mainly for immunity testing and radiated emission pre-testing; small footprint, low cost, modular and relocatable, easily upgradeable to the 733-type and standard 3 m chamber, suitable for SMEs | [1] |
| Minimum Practical Size Chamber | The "733" type, approx. 7 × 3 × 3 m; mainly for RF immunity, emission prediction and free-space emission testing; lower cost, suited to in-house testing by SMEs | [1] |
| Small Anechoic Chamber | Approx. 8 × 4 × 4 m; mainly for RF immunity, emission prediction and free-space emission testing; slightly taller and larger than the minimum practical size chamber | [1] |
| 3 m Method Anechoic Chamber | Approx. 9 × 6 × 6 m; for RF immunity and emission testing of products under 2 m, an internationally adopted alternative to the open area test site | [1] |
| 5 m Method Anechoic Chamber | Approx. 11 × 7 × 9 m; performance superior to the 3 m method over a wide range, with a better correction relationship to the 10 m method, able to test larger EUTs and increasingly adopted | [1] |
| 10 m Method Anechoic Chamber | Approx. 19 × 12 × 9 m; for RF immunity and emission testing of large-volume products, generally considered only for special equipment such as vehicles | [1] |
Provide the EUT dimensions, the standard to meet and test distance, chamber type, required field uniformity, shielded door and waveguide window specifications, plus the layout area requirements for the amplifier room and control room. Confirm with the manufacturer.
Questions before you start
Do the listed values apply to every configuration?
Source: Linkall's system EMC test solution. The specifications below are taken from the RF shielding system for anechoic chambers; the chamber type, dimensions, field uniformity and laboratory layout remain subject to project confirmation. See the notes in each row for the applicable scope.
What should I prepare for a technical discussion?
Provide the EUT dimensions, the standard to meet and test distance, chamber type, required field uniformity, shielded door and waveguide window specifications, plus the layout area requirements for the amplifier room and control room. Confirm with the manufacturer.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.