Standards compliance: meets MIL-STD-464C, SAE ARP5412 and DO-160 Section 23, simulating the continuous direct-effect lightning waveforms A/B/C/D.
Aircraft, Military & SPD Lightning Protection Test System
An aircraft lightning protection test system compliant with MIL-STD-464C, ARP5412 and DO-160 Section 23. Four generators simulate continuous A/AH, B, C/C* and D waveform lightning strikes, supported by a delay trigger and a fully automatic control & measurement system; it is also used for SPD lightning tests.
What this solution covers
Four generators: impulse current (A/AH, D waves), square-wave current (B wave) and DC generator (C/C* waves), with peak values of 200 kA / 2 kA / 800 A.
Control accessories: electronic multi-channel delay trigger (6 channels, 0.1 µs resolution) and a fully automatic control & measurement system, also applicable to impulse voltage chopping.
Technical details & configuration
Source: Linkall's self-developed aircraft lightning protection test system (GPP-2009 series). The specifications below are taken from the manufacturer's aircraft, military & SPD lightning protection test system page; the specific waveform configuration, peak parameters and supply scope remain subject to project confirmation. See the notes in each row for the applicable scope.
| Item | Published information | Source |
|---|---|---|
| Impulse Current Generator :GPP-2009 | output waves: A and AH; front time: less than 37.5 µs; max specific energy: 2×10⁶ kJ/Ω; peak output: 200 kA (10%–100%); | [1] |
| Square-Wave Current Generator:GPP-2009-SW | output wave: 5 ms; duration: 5 ms; peak output: 2 kA (±10%); | [1] |
| DC Generator :GPP-2009-ZL | output voltage: 500 V; output current: 200 A continuous, max 800 A for 0.25 s; power: 100 kVA; | [1] |
| Impulse Current Generator:GPP-2009 | output wave: D; front time: less than 25 µs; max specific energy: 0.25×10⁶ kJ/Ω; peak output: 100 kA (10%–100%); | [1] |
| Electronic Multi-Channel Delay Trigger:GPP-2009-DL | delay time: 0–9.9 µs / 0–99 µs; resolution: 0.1 µs; 6 controllable delay channels; fiber-optic interface, stable and reliable; | [1] |
| Impulse Control & Measurement System | Fully automatic control & measurement system; complex operation sequences can be programmed; configuration adjustable per customer requirements; | [1] |
Provide the DUT (whole aircraft/parts, military equipment or SPD), the standard to meet (MIL-STD-464C / SAE ARP5412 / DO-160 Section 23), required waveforms (A/AH, B, C/C*, D), peak current and energy for each waveform, delay and timing requirements, plus control system and laboratory layout needs. Confirm with the manufacturer.
Questions before you start
Do the listed values apply to every configuration?
Source: Linkall's self-developed aircraft lightning protection test system (GPP-2009 series). The specifications below are taken from the manufacturer's aircraft, military & SPD lightning protection test system page; the specific waveform configuration, peak parameters and supply scope remain subject to project confirmation. See the notes in each row for the applicable scope.
What should I prepare for a technical discussion?
Provide the DUT (whole aircraft/parts, military equipment or SPD), the standard to meet (MIL-STD-464C / SAE ARP5412 / DO-160 Section 23), required waveforms (A/AH, B, C/C*, D), peak current and energy for each waveform, delay and timing requirements, plus control system and laboratory layout needs. Confirm with the manufacturer.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
- 凌茂:飞机、军方、SPD 防雷测试系统 / LinkAll: Aircraft, Military & SPD Lightning Protection Test SystemLegacy website reference
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.