Shanghai Lingmao Electronic Science and Technology Co., Ltd.
TESEQ

IEC 61000-4-31

It applies to single-phase AC powered equipment with rated current ≤16 A for 150 kHz–80 MHz broadband noise immunity testing, meeting the test levels and coupling requirements defined by the standard.

View technical details
IEC 61000-4-31
CAPABILITIES

What this solution covers

01

Standard compliant: Per IEC 61000-4-31, using broadband disturbance signals at specific levels from 150 kHz–80 MHz, with test levels defined by power spectral density (Level 1–3: -60/-50/-40 dBm/Hz) plus custom levels.

02

NSG 4031 main unit: A broadband immunity test system purpose-built for IEC 61000-4-31, with a white-noise generator and four built-in bandpass filters; three power meters measure forward power and VSWR for easy level setting.

03

Integrated amplifier and standalone operation: Built-in amplifier module with >80 W output covers standard Levels 1–3; powerful, user-friendly firmware allows testing without an external PC or control software.

TECHNICAL REFERENCE

Technical details & configuration

The source material is an IEC 61000-4-31 test-solution description listing standard test levels, system composition and device features. Values are not published on this page unless verified. See notes in each row.

Configuration limits are stated per row.
ItemPublished informationSource
ApplicabilitySingle-phase AC equipment with rated current ≤16 A; 150 kHz–80 MHz[1]
Test levelsDefined by power spectral density: Level 1 -60 dBm/Hz, Level 2 -50 dBm/Hz, Level 3 -40 dBm/Hz; custom levels supported[1]
Core generatorNSG 4031 broadband noise generator: white-noise source + 4 bandpass filters + three power meters[1]
Amplifier & operationBuilt-in >80 W amplifier module covering Levels 1–3; firmware runs standalone without external PC/software[1]
Coupling networkCDND M316-16B dedicated coupling/decoupling network, different from standards such as IEC 61000-4-6[1]
Calibration kitCAS CDND31 calibration kit for test-level calibration and setup[1]
Confirm before selection

please provide the standard edition, EUT rated current and supply type, required test level (Level 1–3 or custom), and configuration of the coupling network (CDND M316-16B) and calibration kit (CAS CDND31); the NSG 4031 main unit no longer has a dedicated product page on the manufacturer's website — configuration and availability must be confirmed per project.

FAQ

Questions before you start

Do the listed values apply to every configuration?

The source material is an IEC 61000-4-31 test-solution description listing standard test levels, system composition and device features. Values are not published on this page unless verified. See notes in each row.

What should I prepare for a technical discussion?

please provide the standard edition, EUT rated current and supply type, required test level (Level 1–3 or custom), and configuration of the coupling network (CDND M316-16B) and calibration kit (CAS CDND31); the NSG 4031 main unit no longer has a dedicated product page on the manufacturer's website — configuration and availability must be confirmed per project.

How do I request documentation?

Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.

Sources · checked 2026-11-19
  1. 官网产品页(CDND IEC/EN 61000-4-31)
  2. 官方数据表 PDF

Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.