Standard compliant: Per IEC 61000-4-31, using broadband disturbance signals at specific levels from 150 kHz–80 MHz, with test levels defined by power spectral density (Level 1–3: -60/-50/-40 dBm/Hz) plus custom levels.
IEC 61000-4-31
It applies to single-phase AC powered equipment with rated current ≤16 A for 150 kHz–80 MHz broadband noise immunity testing, meeting the test levels and coupling requirements defined by the standard.
What this solution covers
NSG 4031 main unit: A broadband immunity test system purpose-built for IEC 61000-4-31, with a white-noise generator and four built-in bandpass filters; three power meters measure forward power and VSWR for easy level setting.
Integrated amplifier and standalone operation: Built-in amplifier module with >80 W output covers standard Levels 1–3; powerful, user-friendly firmware allows testing without an external PC or control software.
Technical details & configuration
The source material is an IEC 61000-4-31 test-solution description listing standard test levels, system composition and device features. Values are not published on this page unless verified. See notes in each row.
| Item | Published information | Source |
|---|---|---|
| Applicability | Single-phase AC equipment with rated current ≤16 A; 150 kHz–80 MHz | [1] |
| Test levels | Defined by power spectral density: Level 1 -60 dBm/Hz, Level 2 -50 dBm/Hz, Level 3 -40 dBm/Hz; custom levels supported | [1] |
| Core generator | NSG 4031 broadband noise generator: white-noise source + 4 bandpass filters + three power meters | [1] |
| Amplifier & operation | Built-in >80 W amplifier module covering Levels 1–3; firmware runs standalone without external PC/software | [1] |
| Coupling network | CDND M316-16B dedicated coupling/decoupling network, different from standards such as IEC 61000-4-6 | [1] |
| Calibration kit | CAS CDND31 calibration kit for test-level calibration and setup | [1] |
please provide the standard edition, EUT rated current and supply type, required test level (Level 1–3 or custom), and configuration of the coupling network (CDND M316-16B) and calibration kit (CAS CDND31); the NSG 4031 main unit no longer has a dedicated product page on the manufacturer's website — configuration and availability must be confirmed per project.
Questions before you start
Do the listed values apply to every configuration?
The source material is an IEC 61000-4-31 test-solution description listing standard test levels, system composition and device features. Values are not published on this page unless verified. See notes in each row.
What should I prepare for a technical discussion?
please provide the standard edition, EUT rated current and supply type, required test level (Level 1–3 or custom), and configuration of the coupling network (CDND M316-16B) and calibration kit (CAS CDND31); the NSG 4031 main unit no longer has a dedicated product page on the manufacturer's website — configuration and availability must be confirmed per project.
How do I request documentation?
Email linkall@inlinkall.com with the product name and test requirements, or call +86 21 52831768. The online enquiry form is not yet available. Documentation is supplied in its available language.
Legacy information may not reflect current availability. Confirm the final model, options and specifications in the technical agreement.